E. Specification
1. DC Voltage
2. AC Voltage
3. DC Current
4. AC Current
5. Resistance
6. Diode, Transistor,
Continuity Test
F. Operation Plate
Page
3
4
6
7
9
9
10
11
12
13
14
15
1
Model UT30A: OPERATING MANUAL
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - Model UT30A: OPERATING MANUAL

Table of Contents (1)TitleA. IntroductionB. Safety RulesC. International Electrical SymbolsD. FeatureE. Specification 1. DC Voltage 2. AC Volt

Page 2

E. Specification(2)

Page 3

E. Specification(3)3. DC CurrentRange400µA4mA40mA400mA10AResolution0.1µA1µA10µA100µA10mAAccuracy(1%+2)(1.2%+2)(1.5%+2) Overload Protection: 0.5A/250v

Page 4

E. Specification(4)4. AC CurrentRange400µA4mA40mA400mA10AResolution0.1µA1µA10µA100µA10mAAccuracy(1.3%+5)(2%+5)Overload Protection: 0.5A/250V fuse. Un-

Page 5

E. Specification(5)Range400Ω4kΩ40kΩ400kΩ4MΩ40MΩResolution0.1Ω1Ω10Ω100Ω1KΩ10KΩAccuracy(1%+2)(1.2%+2)(1.2%+2)(1.5%+2)5. ResistanceOverload Protection: A

Page 6

E. Specification(6)6. Diode, Transistor, Continuity TestFunctionDiodeTransistorRangehFEResolution1mV1β0.1ΩInputProtection230V DCor AC230V DCor ACRemar

Page 7

F. Operation Plate1. Liquid Crystal Display2. Data hold or POWER function Button3. Rotary Switch4. Transistor Test Jack5. Common Input Jack6

Page 8 - D. Feature(2)

G. Make Measurements(1)First, set rotary switch to proper position, after several seconds of self-check, the meter will enter measuring state. When “

Page 9 - 1. DC Voltage

1. DC Voltage Measurement (figure 2)G. Make Measurements(2)( figure 2 )1) Never measure voltage value exceeding 500V, although it is possible t

Page 10

G. Make Measurements(3)4) For ranges except 400mV, input impedance 10MΩ, this can cause measuring tolerance at high impedance circuit ,If circu

Page 11

G. Make Measurements(4)2. AC Voltage Measurement (figure 3)Same as DC voltage measurement, however, the meter has auto-rangefunction with initial ran

Page 12

Table of Contents (2)TitleG. Make Measurements 1. DC Voltage Measurement2. AC Voltage Measurement 3. DC Current Measurement4. AC Current M

Page 13 - 5. Resistance

G. Make Measurements(5)3. DC Current Measurement (figure 4)(figure 4)1) This range is manual range. Do not measure, when value between open vol

Page 14 - Continuity

G. Make Measurements(6)3) If the magnitude of current is unknown, you should set rotary switch to the higher range, then adjust to a lower rang

Page 15 - ( figure 1)

G. Make Measurements(7)4. AC Current Measurement (figure 5)Same as DC current measurement.(figure 5)22Model UT30A: OPERATING MANUAL

Page 16

G. Make Measurements(8)5. Resistance Measurement(figure 6)1) To avoid damages to the Meter, when measuring resistance, cut off the power of th

Page 17

3) Wires takes 0.1Ω -0.3Ω tolerance at function of 400Ω when measuringresistance. To get an accurate reading, you can subtract the shortcircuit valu

Page 18 - Ω, this can cause

6. Diode measurement (figure 7)( figure 7)G. Make Measurements(7)1) Cut off the power supply of the object to avoid damages to the Meter when

Page 19 - G. Make Measurements(4)

3) When measuring voltage drop of PN, for a good silicon semiconductor structure, normal positive reading should stay between 0.5V~0.8V. Neg

Page 20

G. Make Measurements(9)7. Transistor hFE Measurement(figure 8)( figure 8)1) Check that the transistor is PNP or NPN type at first.2) Connect the t

Page 21

( figure 9)G. Make Measurements(10)8. Continuity test (figure 9)Before testing continuity, power off and no charge in capacitor to avoiddamages to the

Page 22

9. “Hold”, “Power” Button FunctionG. Make Measurements(11)1) Pressing “Hold” button holds current reading displayed on LCD in open state, press

Page 23 - (figure 6)

A. IntroductionUT30A Multimeter is 3 3/4 digits with steady operations, fashionable structureand highly reliable hand-held measuring instrument. The m

Page 24

H. Fuse and Battery replacement1. Remove inputs & test leads from terminals.2. Remove two rubber feet and two screws from the bottom case.3.

Page 25

I. Included Accessories1. Operating Manual2. Test Leads3. 2 pieces of 1.5V (AAA) Battery31Model UT30A: OPERATING MANUAL

Page 26

~ END ~ * The manual is subject to changes without separate notice. *32Model UT30A: OPERATING MANUAL

Page 27

B. Safety Rules(1)1. Read the manual carefully before use. Use the Meter only as specified in this manual, otherwise, the protection provided by

Page 28 - Ω is a dividing value for

8. When measuring voltage higher than DC 60V or AC 30Vrms, pay extra attention to avoid electric shock.9. Use only 0.5A/250V φ 5X20(mm) fast

Page 29

C. International Electrical SymbolsCAUTION-FOR CONTINUED PROTECTION AGAINST FIRE, REPLACEONLY WITH FUSE OF THE SPECIFIED VOLTAGE AND CURRENTRATINGS.Gr

Page 30 - (figure 10)

”““”“”“”D. Feature(1)

Page 31 - 2. Test Leads

“”D. Feature(2)

Page 32

E. Specification(1)1. DC VoltageRange400mV4V40V400V500VResolution0.1mV1mV10mV100mV1V(0.8%+3)(0.8%+1)(1%+3)Accuracy9Model UT30A: OPERATING MANUAL